How to Compare Operating Table Specifications for Real Procedures

An operating table should be selected for the work it will perform, not for the largest number in a brochure. Review the intended procedures, patient and accessory load, required positions, imaging workflow, table clearance and service conditions together.

Start with the actual operating conditions

Define the procedures planned for the room and list the positions, imaging equipment and accessories used for those procedures. The approved limits for the exact table configuration must cover the combined patient and accessory load throughout the required movements.

Hospital category and a single headline capacity do not determine the correct table. The decision should use the model’s operating instructions, approved configuration limits and the room’s clinical workflow.

Understand static load and powered-movement load

Load figures can describe different conditions. For the WEYUAN WY-400, the approved product records distinguish these two values:

625 kg

Non-operating static load

The table is stationary. This value describes the load the structure can withstand without structural damage under the stated non-operating condition.

420 kg

Maximum load during normal powered movement

This value applies while the table performs powered lifting, tilting, longitudinal travel and other approved movements.

These values are not interchangeable. Confirm the operating condition, accessories and configuration in the approved datasheet and operating instructions before procurement.

Compare movement and positioning requirements

Movement range matters only when it supports the procedures performed in the room. The following WY-400 figures are model-specific reference values from its approved product records.

ItemWY-400 reference valueWhat the buyer should confirm
Tabletop size2100 mm ±100 mm long; 550 mm ±50 mm widePatient support, accessory space and transfer workflow
Height range600 mm ±50 mm to 1050 mm ±50 mmStaff working height, transfer height and equipment clearance
Longitudinal travel350 mm ±50 mmRequired imaging coverage with the selected C-arm and patient orientation
Trendelenburg and reverse TrendelenburgAt least 30°, tolerance ±5°Positions required by the intended procedures
Lateral tiltAt least 20°, tolerance ±5°Positioning range, stability and accessory clearance

Evaluate the table and imaging system together

Longitudinal travel can support radiographic and C-arm workflows, but the travel number alone does not prove usable imaging coverage. Review the table, C-arm, patient orientation and accessories as one arrangement.

  • Confirm the usable imaging field for the intended procedures.
  • Check collision clearance through the required table and C-arm movements.
  • Confirm whether accessories or patient supports restrict longitudinal travel.
  • Record the evaluated configuration so the quotation and installation plan refer to the same arrangement.

Check the room, accessories and service conditions

Selection itemInformation to confirm
Clinical useProcedure list, patient positioning and department requirements
LoadPatient and accessory load under stationary and powered-movement conditions
RoomLayout, transfer route, floor condition and movement clearance
ImagingC-arm model, required field, patient orientation and movement sequence
AccessoriesRequired supports, clamps, attachments and compatibility limits
Power and backup controlLocal supply, installation requirements, battery and manual backup procedures
EvidenceApproved datasheet, operating instructions and configuration-specific test information

Operating table specification questions

Why can an operating table have more than one load figure?

Different figures can apply to different conditions. A stationary structural load is not the same as the load permitted during powered lifting, tilting or longitudinal movement. Ask the supplier to label each value and its test or operating condition.

Is the highest load number automatically the best choice?

No. Load is one part of the decision. The table must also support the required positions, imaging workflow, accessories, room clearance and service conditions.

How should a buyer compare C-arm access?

Evaluate the table and C-arm together. Confirm usable imaging coverage, movement clearance, patient orientation and any restrictions created by accessories.

What information is needed before quotation?

Send the procedure list, expected patient and accessory load, room layout, C-arm model, required positions, power conditions and accessory list. This allows the supplier to review the intended configuration.

Evidence and application limits

The WY-400 figures on this page come from its approved operating manual and white paper, reviewed in the WEYUAN product knowledge base on 18 September 2026. They describe this model and do not create universal selection thresholds for other operating tables, patients or procedures. Final configuration must follow the documents supplied for the exact order.

Send your procedure list and room plan.

WEYUAN can review the intended workflow, load conditions, imaging equipment and accessories before preparing a configuration.

Request Configuration Review